Welling & Crossley, 18kVA, Single Phase, Diesel Generator

Call for price

  • Crossley SLG Series
  • Single Phase
  • 18 kVA at 0.8 pf (Standby)
  • 240V,  14.4 kW,  50Hz
  • Lister Petter TR3-09 Engine
  • 4.6L/hr Fuel consumption (1hr continuous)

Description

The Lister powered LLT18/1 is an 18kVA single phase diesel generator. Complete with Crossley SLG series single bearing, 4-pole, brushless alternator, remote start/stop control system and 90 litre fuel tank. With Lister Petter’s legendary performance and reliability this air cooled generator is perfect for both stationary and prime power applications. Welling and Crossley carries out stringent factory testing including full load testing.

  • Heavy duty fabricated steel baseframe
    The complete generating set is mounted as a whole onto a heavy duty fabricated steel baseframe. Anti-vibration pads are fixed between the engine and alternator feet, and the baseframe, ensuring complete vibration isolation of the rotating assembly.
  • Bunded Fuel Tank (AS 1940-2004 compliant)
    The fuel tank is fully bunded and complies fully with relevant sections in AS 1940-2004. It has a secondary containment compound with a capacity as big or bigger than that of the tank, and is made of surface coated steel. This compound is designed to sufficiantly retain spillage and enable recovery of any spillage. For more information regarding AS 190-2004 compliance refer to the standard, or contact us.
  • Battery Charger
    This trickle charge battery charger ensures that your generator can start up when needed. It has both 12v and 24v charging capabilities.
  • Control Panel with Emergency Stop button
    This control panel can detect both voltage and current and can be started and stopped manually or via remote start stop signals. It displays oil pressure and water/cylinder temperature, and comes standard with an emergency stop alarm, over speed monitor, and graphical LCD monitor.
  • Prime or Standby Power
    Standby: kVA @ 0.8 pf These ratings are applicable for supplying continuous electrical power (at variable loads) in the event of a utility power failure. No overload is permitted on these ratings. Minimum output from alternators are peak continuous rated (as defined in 1SO 8528-3 @ 27°C. Annual hour limitation: 500 hours).
    Prime (continuous): kVA @ 0.8 pf. (Divide standby rating by 1.1). Available for continuous electrical output. There is no hour limitation. 10% overload is available 1 hour in 12. The generating set and this specification is designed for environmental conditions of up to 27°C, up to 152.4 m above sea level and up to 60% relative humidity. Ratings at 0.8 pf.